Follow

Keypad Status Light Conditions

 

Status Light Condition

Definition

Action to Take

Light is Green (continuous)

Machine is on

Load Design

Light is Red (blinking slowly)

Thread break

Re-thread the affected needle

Light is Red (blinking fast)

Machine out of bobbin thread or there is a bobbin break

Replace the bobbin or fix the bobbin break

Light is Green for 2 sec., off for ½  sec.

Machine is in low power shut-down (Sleep Mode)

Wake Mode-Press Start for 3 sec.

 

Sleep mode-Press Stop for 3 sec.

Green light blinking in 1 second intervals - with machines using Main Board 31058-19 (or older)

The machine needs RSA/CSA files

Release the red E-Stop, Check Force Download and Power Cycle.

Light is Red (continuous)

E-Stop is engaged

Release the red E-Stop

Light is Red (continuous)

Sequin Head is turned ON

Turn off Sequin Device- Press Stop + Laser + Frame Back Buttons

Alternating/Blinking between Red and Green

n/a

You will need additional technical assistance.  Here are the available Melco Technical Support options.

Green Light stays on ~4 seconds and turns off for ~15 seconds.

 

n/a

You will need additional technical assistance.  Here are the available Melco Technical Support options.

 

 

 

Was this article helpful?
0 out of 0 found this helpful