Follow

Freed Needle Case Lower Bar

Verify that the Needle Case Lower Bar PN: 30627 is still being held by the Lower Color Change Bracket PN: 30689-01.


freed1.png

 

freed2.png
The red arrow points to the Needle Case Lower Bar, the blue arrow points to the Lower Color Change Bracket

1.  If the Lower Bar is free, remove the two screws that attach the Change Bracket to the machine.

freed3.png

2.  Verify if the Change Bracket is bent.

3.  If possible, reinstall the Change Bracket making sure it is on the outside of the Lower Bar. If the Lower Bar is pulled forward, away from the bracket, check for any other obstructions holding the Needle Case forward.


freed4.png

 

4.  The Presser Foot might be holding the case forward. If it is, try Removing the Needle Bar.

freed5.png

5.  If the Lower Bar is not pulled forward, the freed Case fixed.

6.  If the situation remains unresolved, you will need additional technical assistance. Here are the available Melco Technical Support options.

Was this article helpful?
0 out of 0 found this helpful